Openreach ACCN :          OR 061 OR
 
   
New      
Effective Date 12-Dec-07    
Notification Date 11-Dec-07      
OPENREACH ACCESS CHARGE CHANGE NOTICE
ACCN NUMBER: OR 061
PRODUCT: LLU Plan & Build “Ancillary Bolt Ons”
EFFECTIVE DATE: 12-Dec-07
SUBMITTED TO OFCOM ON:   11-Dec-07
 Price List OR
 
   
 Section : Local Loop Unbundling  
 Product : Plan & Build  
 Page : Accomodation  
 Reference : 2.2.1      
Schedule 09 (Note 2)
  Operative Date Until Charge
£ Exc VAT
BASIS (BT Assisted Site Delivery Service)  fixed charge (Note 8) 31/05/2001   325.00
Site Access  (Note 21) 12/06/2003   308.47
Handover  12/06/2003   256.15
Security partitioning annual rental per site charge (Note 22) 08/12/2003   116.90
"Ancillary Bolt On" POP Enchancements (Note 28) 12/12/2007   Bespoke
Notes: 
1) Charges may be payable on submission by the Operator of incomplete or inaccurate requests and equal to 25% of the appropriate charge.
2) All charges will be due and payable by the relevant Due Date in accordance with the Agreement. 
3) Charges for Operator Equipment Room Works will vary depending on location, room size, equipment installed, amount of conversion required etc. Bespoke rooms built to the same standard as the Co-location Hostel specification will be charged on the same basis as Co-location Hostel pricing principles.
4) This charge will be payable quarterly in advance on 1st Jan, 1st April, 1st July or 1st October depending on when the relevant service or product starts or is deemed Ready for Service. BT will apportion rental on a daily basis for the initial period if that initial period is less than a Quarter.
5) Bespoke charges will be adjusted if appropriate during the Works. 
6) Servicing of equipment in addition to standard equipment available in a standard Co-location Hostel bay.
7) This usage rate is applied to both Standard Electricity and Standby Electricity.
8) This is charged per day or part thereof on a per MDF Site basis. This charge also applies for abortive deliveries as a result of an Operator request.
9) The billable area is rounded up to the nearest square decimetre (1/100 of a square metre).
10) Operators will be credited with £1375 against the estimated Operator Equipment Room Works and associated invoices.  Only applicable if operator proceeds to build.
11) The billable area is calculated by the area of the number of Rack Space Units ordered and multiplied by 3.85.  The billable area is indicated in the offer document. 
12) This will automatically be provided as part of the Co-mingling order dependant on the number of rack space units ordered.
13) These costs are for providing the required power and cooling for the maximum power rating the Operator orders for the Co-mingling facilities.
14) These charges are raised quarterly in arrears.
15) These charges are raised monthly in arrears.
16) The date these prices apply is related to the completed/ handover date and is not dependent on when the order is placed.
17) Planned access = 5 working days or greater notice.  Unplanned access = less than 5 working days notice.  Average response time = 4 hours.  Business hours are Monday – Friday 09:00 – 17:00
18) These prices are calculated using a minimum of 4 hours including BT travelling time.
19) This charge will apply to all orders whether for ESS or non ESS supply.
20) This charge applies only if sub meter is requested on the initial order. Subsequent order for sub metering will raise a bespoke charge.
21) Applicable to co mingling. Charge covers provision / re programming of electronic access cards and provision of external gate keys.
22) Charge applicable to co-mingling installations only.
23) This audit is renewable on a 12 monthly basis as per ISO registration timescales.
24) Where DC Power options are ordered, the maximum AC power capacity will be supplied.
25) This cancellation schedule applies to Co Mingling orders only.
26) This charge is applied when a forecast order for a co mingling product is not followed up with a firm order.
27) On completion of upgrade, all applicable rental charges will move to the upgraded product rates.
28) Ancillary bolt ons include :- Post intial build provision of UPS rectifiers, HDF security doors, UPS power lead restraints. Replacement of existing batteries with higher specification units, additional battery string, replacement of exisiting UPS with higher specification unit, replacement of existing UPS internal battery unit with higher specification battery to provide greater UPS autonomy, ASS600 upgrade, BBUSS fusing and lighting upgrade HDF9 to HDF18 upgrade, Post build testing.
    British Telecommunications plc
    Registered office:
    81 Newgate Street
    London EC1A 7AJ
    Registered in England and Wales No. 1800000
Date: 11 December 2007    www.openreach.co.uk